Some physiological and chemical properties of horse and cow blood samples under effect of some different types of anticoagulants
Main Article Content
Abstract
The purpose of the present study is to determine and compare the anticoagulants, Ethylene diamine tetra acetic acid, Sodium oxalate, Sodium citrate and heparin in blood samples of horse and bull, through estimation of (Hemoglobin, Packed Cell Volume and Plasma Platelets Count) and plasma physical properties (clarity and volume) and some chemical properties (pH and calcium ion concentration). Five Blood samples were obtained from five stallions and five bulls (20 ml/sample) and were divided as 5 ml in four test tubes containing Ethylene diamine tetra acetic acid, sodium oxalate, sodium citrate and heparin at the College of Veterinary Medicine, University of Diyala. Hemoglobin and packed cell volume were estimated immediately and then the blood samples were centrifuged for 15 min. at 3000 rpm to obtain plasma for evaluating the physical and chemical properties specified above. The horse blood samples pertaining data had no significant elevation in hemoglobin concentration and packed cell volume in Ethylene diamine tetra acetic acid group as compared to other groups, beside having no significant changes in pH between the four treated groups while there was a significant increase in plasma volume of oxalate and citrate as compared to Ethylene diamine tetra acetic acid and heparin, and there was a significant increase in plasma platelet count of Ethylene diamine tetra acetic acid group as compared to heparin. As well there was a significant decrease of calcium ion concentration in Ethylene diamine tetra acetic acid, oxalate and citrate as compared to heparin, while the results of bull blood samples revealed that the hemoglobin and Packed Cell Volume were significantly higher in heparin group than in the oxalate and citrate groups with non significant differences with Ethylene diamine tetra acetic acid group. The plasma obtained from different types of anticoagulants appeared with a high degree of clarity, and the volume of plasma had no significant increase in oxalate and citrate group as compared to other groups. The Plasma Platelet Count and calcium concentration significantly increased in heparin group as compared to other groups. In conclusion, the Ethylene diamine tetra acetic acid was more reliable for horse blood samples while the anticoagulant heparin was more reliable anticoagulant for bull blood samples.
Received: 11/9/2017
Accepted: 7/1/2018
Publishing: 28/6/2018
Downloads
Article Details
How to Cite
References
Agnese, S.T.; Spierto F.W. and Hannon W.H. (1983). Evaluation of four reagents for delipidation of serum. Clin. Biochem., 16:98100.
https://doi.org/10.1016/S0009-9120(83)90676-8
Guder, W.G.; Ehert, W.; da FonsecaWollheim, F.; Heil, W.; Muller-Plath, O. and Topfer, G. (1998). Serum or plasma or Whole blood? Which anticoagulants to use? Lab Med., 22:297-312.
Wittkowsky, A.K. (2001). Drug inter actions update :drugs, herbs and oral anticoagulation. J. Thromb. Thrombolysis. 1:67-71.
Guder, W.G. (2001). The quality of diagnostic samples. Blood Gas News 10:1824.
Narayanan, S. (1993). Effect of anticoagulants used for blood collection on laboratory tests. Proc JCLA., 7:1-10.
Di Nisio, M.; Middeldorp, S. and Buller, H.R. (2005). Direct thrombin inhibitor. N. Engl. J. Med. 353(10):1028-1040.
https://doi.org/10.1056/NEJMra044440
Banifi, G.; Salvagno, G. and Lippi, G. (2007). The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulants for diagnostic purposes. Clin. Chem. Lab. Med., 45(5):565-576. https://doi.org/10.1515/CCLM.2007.110
NCCLS document H21-A3 (2000). Collection, transport and processing of blood specimens for coagulation testing and general performance of coagulation assays. Wayne, PA: 3rd ed.
Eden, R.E.; Linhardt, R.J. and Weiler, J.M. (1993). Heparin is not just an anticoagulant anymore: six and one half decades of studies on the ability of heparin to regulate complement activity. Complement profile. 1:96-120.
Coles, E.H. (1974). Veterinary Clinical Pathology. Philadelphia, London, Toronto.2nd Ed. 5:158-160.
Steel, R.G. and Torrie, J.H. (1988). Principle of Statistic a Biometrical Approach 2nd Ed. McGraw-Hill, New York. Pp:693-696.
Turkson, P.K.; Ganyo, E.Y. (2015). Relationship between hemoglobin and packed cell volume in cattle blood samples. Onderstepoort J. Vet. Res., 82(1):1-5. https://doi.org/10.4102/ojvr.v82i1.863
Pramina, K.V.; Mincy, P.T.; Joseph, P.A.; Lisha, V.; Mercy, K.A. and Ramnath, V. (2013). Levels of calcium, sodium and potassium in plasma as influenced by anticoagulants. J.Vet. Anim. Sci., 44:72-75.
Majeed, H.M. and Salih, K.J. (2007). Compares the effect of use some anticoagulants on the estimation of some blood parameters in human. J. Missan Res., 3(6):1-14.
Ceron, J.J.; Subiela, S.M.; Hennemann, C. and Tecles, F. (2004). The effects of different anticoagulants on routine canine plasma biochemistry. Vet. J., 167: 294-301. https://doi.org/10.1016/j.tvjl.2003.09.009
Grondin, T.M. and Dewitt, S.F. (2010). Normal hematology of the horse and donkey. In: Schalm's Veterinary Hematology. Weiss, D.J. and Wardrop, K.J. (eds.), Pp: 821-828, Wiley Blackwell Inc.
Kamal, H. and Mohri, M. (2015). Effect of heparin, citrate and EDTA on plasma biochemistry of cat: compression with serum. Rev. Med.Vet.,166(9-10):275-279.
Sobech, P.; Stopyra, A.; Kuleta, Z.; Zbanyszek, M. and Milewski, S. (2005). Acid base balance parameters of atrial, venous and capillary blood in sheep. Bull. Vet. Inst. Pulawy., 49:125-127.
Callan, M.B.; Shofer, F.S. and Catalfamo, J.L. (2009). Effect of anticoagulant on pH, ionized calcium concentration and agonist platelet rich plasma. Am. J. Vet Res., 70(4):472-477. https://doi.org/10.2460/ajvr.70.4.472.
O'Shea, C.M. (2014). Comparison of Platelet Counting Technologies in Equine Platelet Concentrates. Thesis Master of Science in Biomedical and Veterinary Sciences. https://doi.org/10.1111/j.1532-950X.2014.12290.x
Kasten, P.; Vogel, J.; Geiger, F.; Niemeyer, P.; Luginbühl, R. and Szalay, K. (2008). The effect of platelet-rich plasma on healing in critical-size long-bone defects. Biomaterials. 29(29):3983-3992. https://doi.org/10.1016/j.biomaterials.2008.06.014